West Control Solutions presents a range of thyristor power controllers which have been designed to switch 2 legs of 3 phase loads. These thyristor units are ideal for 3 phase configuration, resistive load, without neutral connection.
Relay S – 2PH = Simple on/off firing with a DC logic input, time proportioned burst firing with a DC linear input (basic firing selectable between 4,8 or 16 cycles)
Relay M - 2 PH = Fully adjustable burst firing (3 to 255 cycles), front panel display & keypad plus RS485 comms as standard
front panel display & RS485 comms
PMA3000 - 2PH = More complex load requirements such as feedback and current limit
Next Steps:
|
Ideal for:
- Normal Resistance
- Medium and Long Wave IR load types
|
Benefits & Features:
- Integrated fuse + fuse holder is necessary to have a complete
- power control zone including current transformer and optional circuit board
- Flat Cable Wiring System (option) to connect in plug in mode many Revo S
- when HB alarm or analog input are used
- Input signal: SSR, Analog as an option
- Zero Crossing, Burst Firing available at 4, 8 or 16 Cycles at 50%
- of Power demand
- Electronic fully isolated from power with constant current drain on input.
- Heater Break alarm option to diagnose partial or total load failure
- and Thyristor Short circuit
- Fuse and Fuse holder available as an option
- Current transformer integrated (with Heather Break option)
- Special design for Heat sink with very high dissipation value
- Comply with EMC, cUL (pending)
- DIN RAIL side by side mounting
- IP20 Protection
|
Specification:
- Up to 700A
- 3 wire
- 24Vac to 600Vac Supply
- DC Logic input
- 4-20mA or 0-10V DC linear inputs
- Zero Cross or Burst Firing (4, 8 or 16 cycles @50% power demand)
|
Next Steps:
|
Ideal for:
- Normal Resistance
- Short, Medium & Long Wave IR load types
|
Benefits & Features
- Specifically designed to be an Universal Unit
- RS485 Comm. MODBUS Protocol Standard
- Frontal Key Pad to configure the unit and to read V,I and Power
- Configurablity via RS485, USB Port and frontal Key Pad
- Microprocessor based electronic circuit fully isolated from power
- Universal input signal: RS485,Pot, Analog and SSR
- Firing Mode: Zero Crossing and Burst Firing Mode with programmable cycle time
- Configurable Control Mode: V and VxI
- Heather Break alarm to diagnose partial or total load failure and Thyristor Short circuit
- Digital input configurable
- Fuse and Fuse Holder Standard
- Current transformer integrated in Fuse Holder
- Comply with EMC, cUL pending
- IP20 Protection
- DIN RAIL mounting
|
Specification:
- 3 wire
- 24Vac to 690Vac Supply
- DC logic (SSR)
- 4-20mA or 0-10V DC linear inputs
- 10K Pot or RS485 Comms input
- Zero Crossing
- Burst Firing
|
Next Steps:
|
Ideal for:
- Resistive
- Inductive
- Transformer and complex load types requiring current limit and power control modes
|
Benefits & Features:
- Inputs, firing modes, control modes and loads types.
- Integrated fixed fuses and all what is necessary to have a complete power
- control zone including current transformer and optional circuit board
- Two leg switching three wires load star or delta connections.
- Suitable to drive resistive loads and three phase transformer.
- Frontal Key Pad to control the unit and to read power, current and voltage value.
- Universal Input signal with automatic zero/span calibration.
- Universal Firing modes, customer configurable via Rs485 comm. Modbus or
- communication port as Burst Firing, Single Cycle and Delayed Triggering.
- Power, voltage control mode
- Unbalanced load and Heater Break Alarm.
- RS 485 port. Modbus protocol.
- Comply with EMC, cUL us (option)
- IP20 Protection
|
Specification:
-
330V to 600VAC Supply
- 4-20mA
- 0-10V DC linear
- 10K potentiometer or RS485 comms input
|
Next Steps:
|
Ideal for:
- Normal resistive & transformer coupled with normal resistive load types
|
Powerstack is a Full digital and universal Thyristor unit based on a very powerful dedicated micro configurable via serial communication port for all inputs, firing modes, control modes and loads types.
Benefits & Features:
- Suitable to drive resistive, inductive, transformer with normal resistor
- Two legs switching three wires loads STAR or DELTA connection
- Frontal Key Pad standard to configure all the internal functions and
- parameters.
- Four Analog output configuirable
- Six Digital input
- Four realay output
- Universal Input signal with automatic zero/span calibration.
- Universal Firing modes, customer configurable via Key Pad or
- communication port as Burst Firing or Delayed Triggering
- Universal Feed back modes
- Soft Start can be used in addition to Burst Firing and Phase Angle.
- Unbalanced load and Heater Break Alarm.
- RS 485 port. Modbus protocol
- Comply with EMC
- IP20 Protection
|
Specification:
- 3 wire
- 24Vac to 690Vac Supply
- 4-20mA or 0-10V DC linear inputs
- 10K Pot or RS485 Comms input
- Burst Firing
- Delayed Triggering + Burst Firing
|